Point Drain vs. Linear Drain for Custom Shower Trays

See how point and short-end linear drains change the slope, outlet position and space below the same 1,200 × 800 mm custom shower tray.
LuCharlotte LuCharlotte 6 分以内に読めます 更新済み

Start with the waste pipe, the space below the tray and the level at the shower entry. A point drain is a practical choice when its outlet lines up with a usable pipe route. A short-end linear channel makes sense when the layout calls for the fall to run towards one end and there is room for the channel, fitting and pipe. Both can meet the bathroom floor at a flush entry. In the two Funtek layouts below, the linear option needs 15 mm more recess at the fitting.

Compare Both Layouts on the Same 1,200 × 800 mm Tray

These two Funtek reference layouts have the same outside dimensions, the same wall orientation and the same open short end at the entry. Water runs to an offset opening on the point-drain tray. On the linear tray, it runs towards a channel at the opposite short end from the entry, then leaves through one concealed waste.

Point-drain plan with a 1,200 by 800 mm footprint, 90 mm tray opening and arrows approaching the offset drain
Point-drain plan. The centre of the opening is 400 mm from each of the two edges shown.
Short-end linear-drain plan with a 660 by 120 mm channel and a separately dimensioned concealed 52 mm opening
Linear-drain plan. The concealed opening is 140 mm from the drain-end tray edge.

Swipe sideways on a phone to compare and tap a photo to enlarge it.

What to compare Point drain Short-end linear drain
Cover examples White Vein square point-drain cover with round perforations Grey Breccia exposed short-end linear grille
Tray footprint and entry 1,200 × 800 mm, flush entry in the section shown 1,200 × 800 mm, flush entry in the section shown
Where water enters Ø90 mm tray opening beneath the point cover 660 × 120 mm integral channel leading to a concealed Ø52 mm opening
Centre of the opening below the cover 400 mm from the drain-end tray edge and 400 mm from the back edge 140 mm from the drain-end tray edge and 400 mm from the back edge
Planning recess at the fitting 110 mm below the finished entry level 125 mm below the finished entry level, at the channel

Dimensions apply to the two layouts shown in the Funtek drawing set. Check the approved drawing for the tray and waste fitting on your order.

Download the 1,200 × 800 mm Drainage Comparison

Check the Waste Pipe Position Before Choosing the Cover

Mark the wall lines, tray edges and existing pipe connection on one plan. For a point drain, give the centre of the opening from two tray edges and mark the direction the outlet elbow needs to face. For a linear drain, show the length and width of the channel, its distance from the wall and the centre of the concealed waste separately. On the drawings above, moving from the point opening to the linear waste moves the opening centre 260 mm closer to the drain-end edge. Both fittings discharge sideways in the illustrated configuration. The elbow and pipe route still need to be checked on the plan and section.

In a retrofit, put the existing pipe and any fixed obstructions on the same drawing before choosing. If only one opening can connect to the existing waste within the available space, shortlist that layout first. Where both fit, compare the floor fall and the entry detail.

White Vein product view with a small square point-drain cover offset towards one end
White Vein appearance example with a compact point cover.
Grey Breccia product view with an exposed linear grille along the short end
Grey Breccia appearance example with a grille along the short end.

Compare the Fall, Threshold and Space Below the Tray

In the point-drain plan, fall arrows approach the opening from several directions. In the short-end channel plan, they run along the tray towards the drain end. Both sections show a 0 mm step at the entry, with recess depths measured down from the same finished floor level.

Point-drain section A–A with a flush entry, 110 mm planned recess and a lateral waste connection
Point-drain section A–A. The recess is measured below the finished entry level.
Linear-drain section B–B with a flush entry, 15 mm channel projection, 125 mm recess and a lateral waste connection
Linear-drain section B–B. The extra 15 mm is at the channel in this assembly.

The point section reserves 110 mm at the fitting, with 30 mm of tray and 80 mm underneath. The linear section reserves 125 mm, allowing for the same 30 mm at the tray edge, a 15 mm channel projection and another 80 mm below it for the fitting. The downstream pipe may need more depth as it falls towards the branch. Check the outside dimensions of the elbow, union and pipe along that route.

Suppose the site has 115 mm at each proposed fitting position. Measured from the same finished entry level, the point-drain reference leaves 5 mm against the drawing’s allowance and the linear reference is 10 mm short. The point layout is worth checking first. Ask the installer to confirm whether the pipe and fittings also fit along the entire run.

Customer photograph of a point-drain tray inside a glass shower enclosure
Customer installation with a point drain. This photo shows the visible layout.
Customer photograph of a white striped shower tray with a short drain grille at the far end
Customer installation with an end drain. The pipe connection is below the tray.

Choose the Grate and Confirm What Comes with the Tray

A compact point cover, an exposed linear grille and a concealed slot are three visible options. The cover is what you see from above. The waste fitting below it still needs to match the opening, installation height and pipe connection. Ask how the cover lifts out and what access is available for cleaning the trap.

Three tray illustrations with a compact point cover, an exposed linear grille and a concealed slot
Shown from left to right are a point cover, an exposed linear grille and a concealed slot.
Stone cover over a linear drain with a narrow visible slot
A stone-covered linear drain shows how a concealed slot reads at floor level.

Both reference fittings are listed under the funtek-paisui designation. Identify the point or linear configuration on the order alongside the opening and outlet direction.

  • The reference tray includes a removable stainless steel cover. The short-end channel is an integral part of the linear tray shown.
  • The reference drain kit contains the drain body with a removable trap, a 45° outlet elbow, a union and seals. Both drawings show side discharge. The specification lists a DN 40/50 connection, and the example drawings show a site Ø40 mm waste pipe.
  • The installer supplies the site pipework, including the downstream waste pipe and any couplers or adapters it needs. Check the final kit contents and any alternate fitting on the quotation.

See the sintered stone shower tray collection to compare finishes and visible drain options.

Mark Up Your Drawing Before Requesting a Quote

A sketch is enough to start a conversation. Put these details on the plan and section when the installer is ready to check the layout.

  1. Finished tray size, walls, entry edge and any cut-outs.
  2. Drain opening or channel, outlet centre from two edges and outlet direction.
  3. Fall direction, finished entry level, available recess at the fitting and the pipe route to the branch.
  4. Preferred cover and a list of the parts you want included in the quotation.
White tray with a stepped corner cut-out beside a short-end grille
Mark the cut-out and drain against the same wall reference on the plan.
Angled white tray fitted inside a glass corner shower enclosure
Include the enclosure and entry edge on the plan when the opening is angled.

Use the fillable shower tray measuring sheet in the technical guide to record the finished opening, cut-outs, drain coordinates and entry condition. The installer can use the approved tray and fitting drawings to coordinate support, waterproofing and the site waste connection.

Ask About Shower Tray Drain Options

Ask about the available tray finishes, compatible drain parts or prices. If you already have a sketch, send it with your question.

Point and Linear Shower Tray Drain Questions

01

Do I measure the linear channel from the finished wall or from the tray edge?

State the datum on the drawing. In the reference linear layout, the channel body starts 80 mm from the tray edge, or 83 mm from the finished wall when the shown 3 mm joint is included. The surface recess starts at 90 mm from the tray edge, or 93 mm from the wall. These are two different features.

02

Does the Ø90 mm or Ø52 mm dimension tell me which pipe to buy?

Those dimensions identify the openings around the tray and channel. The pipe connection is specified at the outlet fitting. For the two configurations shown, the connection is listed as DN 40/50 and the example sections show a site Ø40 mm waste pipe. Check the fitting and pipe together.

03

Can I mirror a tray for a second bathroom?

Send the mirrored plan with its wall and entry labels. Give the drain centre from the revised reference edges and mark the outlet elbow direction. For repeated rooms, label left- and right-handed positions on the order so both the tray and the waste route can be checked.

04

Can I switch to a vertical waste after the tray drawing is approved?

Have the tray supplier and installer review the change before fabrication. A vertical fitting changes the connection path and may change the space required underneath. Confirm the replacement fitting, opening and section for the configuration being ordered.

05

What if the same drain name appears on both quotations?

Ask for the point or linear variant and a parts list tied to the quoted tray. Compare the opening, outlet direction, cover and drain-kit contents. The two reference configurations share the funtek-paisui designation, so the configuration on the quotation identifies which set is intended.